  Range  
  mV -2000.0 to 2000.0 mV
  pH -2.000 to 20.000 pH
  ISE 1 x 10-6 to 9.99 x 1010
  Temperature -5.0 to 105.0°C/23 to 221°F/268.2 to 378.2 K
  Resolution  
  mV 0.1 mV
  pH 0.1/0.01/0.001 pH
  ISE 1, 0.1, 0.01
  Temperature 0.1°C/0.1°F/0.1K
  Accuracy
(@25ºC/77ºF)
 
  mV ±0.1 mV
  pH ±0.001 pH
  ISE ±0.5% monovalent; ±1% divalent
  Temperature ±0.1°C/±0.2°F/±0.1K (excluding probe error)
  Burette Sizes 5, 10, and 25 mL
  Burette Resolution 1/40000
  Display Resolution 0.001 mL
  Dosing Accuracy  ±0.1% of full burette volume
  Display 5.7” (320 x 240 pixel) backlit color LCD
  Languages English, Portuguese, Spanish
  Methods load up to 100 methods (standard and user-defined)
  Burette Auto-Detection burette size is automatically recognized when inserted into the unit
   Programmable Stirrer propeller type, 100-2500 RPM, automatically held within 10% of the set value, resolution 100 rpm
  Flow Rate user-selectable from 0.1 mL/min to 2 x burette volumes/min
   Temperature Compensation manual or automatic (ATC)
   End-point Determination equivalence point (1st or 2nd derivative) or fixed pH/mV value
   pH Calibration up to five point calibration, eight standard buffers and five custom buffers
   mV Calibration single point offset
   ISE Calibration up to five point calibration, seven standard solutions and five user defined standards
   Potentiometric Titrations acid-base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, ion-selective, argentometric, back titrations and titre determination
  Measurement Units user specified expression of concentration units to suit specific calculation requirements
   Real Time & Stored Graphs mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve, in pH-mode, mV-mode or ISE mode; pH/mV/concentration values versus time-datalogging results
   Data Storage up to 100 titration and pH/mV/ISE reports
   USB Host (Side) flash drive compatibility for transfers of methods and reports
   Peripherals (Rear) connections for VGA display, PC-keyboard, parallel printer, USB device input, RS232, interface for future expansion
   GLP Conformity instrumentation data storage and printing capabilities
   Operating Environment 10 to 40°C (50 to 104°F), up to 95% RH
   Storage Environment -20 to 70°C (-4 to 158°F), up to 95% RH
   Power “-01” models: 115VAC; “-02” models: 230VAC; 50/60 Hz
   Dimensions 390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in)
   Weight approximately 10 kg (22 lbs.) with one pump and stirrer assembly