HANNA - edge?Multiparameter pH Meter (HI2020) + Free Calibration Certificate

HANNA - edge?Multiparameter pH Meter (HI2020) + Free Calibration Certificate

16 sold in last 24 hours

Rs. 0.00

 

BRAND HANNA
MODEL HI2020
pH Range -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV
pH Resolution 0.001 pH, 0.01 pH, 0.1 mV
pH Accuracy ±0.002 pH, ±0.01 pH, ±0.2 mV
pH Calibration 5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01
pH Temperature Compensation ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*
pH CAL Check (electrode diagnostics) Probe condition, response time, glass and reference junction diagnostics ( HI 11311 & HI 12301 only)
EC Range 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)**
EC Resolution 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater)
EC Calibration 1 point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm
TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**, with 0.80 conversion factor
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Calibration through EC calibration
EC/TDS Temperature Compensation ATC (0.0 to 100.0ºC; 32.0 to 212.0 °F), NoTC
Temperature Correction Coefficient 0.00 to 6.00%/°C (for EC and TDS only), default value is 1.90%/°C
EC to TDS Conversion Factor 0.40 to 0.80
Salinity (% NaCl) Range 0.0 to 400.0% NaCl***
Salinity (% NaCl) Resolution 0.1% NaCl
Salinity (% NaCl) Accuracy ±1% of reading (@25ºC/77ºF)
Salinity (% NaCl) Calibration 1 point with HI 7037L 100% NaCl sea water standard
Salinity (PSU) Range 2.00 to 42.00 PSU***
Salinity (PSU) Resolution 0.01 PSU
Salinity (PSU) Accuracy ±1% of reading (@25ºC/77ºF)
Salinity (PSU) Calibration through EC calibration
Salinity Range 0.0 to 80.0 g/L***
Salinity Resolution (ppt) 0.01 g/L
Salinity Accuracy (ppt) ±1% of reading (@25ºC/77ºF)
Salinity Calibration (ppt) through EC calibration
Oxygen, Dissolved Range 0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation
Oxygen, Dissolved Resolution 0.01 ppm, 0.1% saturation
Oxygen, Dissolved Accuracy ±1 digit, ±1.5% of reading
Oxygen, Dissolved Calibration one or two points at 0% (HI 7040 solution) and 100% (in air)
Oxygen, Dissolved Temperature Compensation ATC: 0 to 50 ºC; 32.0 to 122.0 °F
Salinity Compensation 0 to 40 g/L (with 1 g/L resolution)
Altitude Compensation -500 to 4000 m (with 100 m resolution)
Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F
Temperature Resolution 0.1 °C, 0.1 °F
Temperature Accuracy ±0.5 °C, ±0.9 °F
pH Electrode HI11310 pH electrode (included)
Logging Type Manual log-on-demand (Max. 200 logs); Manual log-on-stability (Max. 200 logs); Interval logging *** (Max. 600 samples; 100 lots)
Logging Memory up to 1000*** records
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 230VAC to 5 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)

Weight

250 g (8.82 oz)

Hanna Instruments is proud to introduce the world’s most innovative pH meter: edge®. edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with a simplified menu and options. For those who require advanced features there is the full featured standard operating mode. The edge HI2020 pH kit can be upgraded at any time with additional probes to measure Conductivity or Dissolved Oxygen.

Digital Electrodes

edge electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge once the electrode is plugged in. These digital electrodes also feature an easy to plug in 3.5 mm connector so you never have to worry about the right angle or aligning pins.

Sensor Check

When used with Hanna’s pH electrodes equipped with a matching pin, edge constantly checks the impedance of the pH measuring electrode to notify you in real time in the event of glass breakage. During calibration, Sensor Check checks the state of the junction. The reference junction is also evaluated and reported on the display.

3.5 mm Probe Input

Plugging an electrode in has never been simpler; no alignments, no broken pins, just connect the 3.5 mm plug and get started.

Wall Mount

Using the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built-in connector to power edge and charge its batteries. edge's zero footprint is designed to save you valuable benchtop space.

Cradle and Electrode Holder

edge is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge securely in place at the optimum viewing angle.

Two USB Ports

edge includes one standard USB for exporting data with a flash drive and a second micro USB port for you to connect to a computer for file export and for charging your edge when the cradle is not available.

Data Logging

edge allows you to store up to 1000 log records of data. Data sets include readings, GLP data, date and time.

Two Operating Modes

edge can be used in Extended or Basic Operating Modes. Extended Mode enables all features available while the Basic Mode reduces the amount of features to a very simple operation. For example, in extended mode edge offers 5 point calibration with 2 custom buffers while in basic mode calibration can only be performed to 3 points with 5 preprogrammed buffers.

 

Hurry Up! Only 10 Left in Stock!

In Stock Unavailable

T/L/MPT/HAN/XXX/005

Ask for price

10

Have a question?