{"product_id":"xlpe-cable-curing-chamber","title":"XLPE Cable Curing Chamber","description":"\u003cp data-start=\"2291\" data-end=\"2585\"\u003eThe \u003cstrong data-start=\"2295\" data-end=\"2324\"\u003eXLPE Cable Curing Chamber\u003c\/strong\u003e is specially designed for \u003cstrong data-start=\"2351\" data-end=\"2437\"\u003ethermal curing and heat aging of XLPE (Cross Linked Polyethylene) insulated cables\u003c\/strong\u003e. The chamber maintains a \u003cstrong data-start=\"2463\" data-end=\"2498\"\u003euniform temperature environment\u003c\/strong\u003e, which is essential for proper cross-linking and curing of cable insulation materials.\u003c\/p\u003e\n\u003cp data-start=\"2587\" data-end=\"2787\"\u003eIt is widely used in \u003cstrong data-start=\"2608\" data-end=\"2687\"\u003ecable manufacturing plants, electrical laboratories, and testing facilities\u003c\/strong\u003e to evaluate the performance and durability of cable insulation under controlled heating conditions.\u003c\/p\u003e\n\u003cp data-start=\"2789\" data-end=\"2964\"\u003eThe chamber is equipped with \u003cstrong data-start=\"2818\" data-end=\"2906\"\u003eprecise temperature control, uniform air circulation, and efficient heating elements\u003c\/strong\u003e, ensuring consistent curing and reliable testing results.\u003c\/p\u003e\n\u003chr data-start=\"2966\" data-end=\"2969\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"2971\" data-end=\"2986\"\u003eKey Features\u003c\/h2\u003e\n\u003cp data-start=\"2988\" data-end=\"3375\"\u003e• Designed for \u003cstrong data-start=\"3003\" data-end=\"3045\"\u003eXLPE cable curing and heat aging tests\u003c\/strong\u003e\u003cbr data-start=\"3045\" data-end=\"3048\"\u003e• \u003cstrong data-start=\"3050\" data-end=\"3086\"\u003eUniform temperature distribution\u003c\/strong\u003e inside the chamber\u003cbr data-start=\"3105\" data-end=\"3108\"\u003e• \u003cstrong data-start=\"3110\" data-end=\"3150\"\u003eDigital \/ PID temperature controller\u003c\/strong\u003e for accurate control\u003cbr data-start=\"3171\" data-end=\"3174\"\u003e• High efficiency \u003cstrong data-start=\"3192\" data-end=\"3219\"\u003eelectric heating system\u003c\/strong\u003e\u003cbr data-start=\"3219\" data-end=\"3222\"\u003e• \u003cstrong data-start=\"3224\" data-end=\"3254\"\u003eForced air circulation fan\u003c\/strong\u003e for uniform heating\u003cbr data-start=\"3274\" data-end=\"3277\"\u003e• Stainless steel inner chamber for durability\u003cbr data-start=\"3323\" data-end=\"3326\"\u003e• Energy efficient insulated chamber construction\u003c\/p\u003e\n\u003chr data-start=\"3377\" data-end=\"3380\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"3382\" data-end=\"3409\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3411\" data-end=\"3956\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3411\" data-end=\"3440\"\u003e\n\u003ctr data-start=\"3411\" data-end=\"3440\"\u003e\n\u003cth data-start=\"3411\" data-end=\"3423\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"3423\" data-end=\"3440\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3470\" data-end=\"3956\"\u003e\n\u003ctr data-start=\"3470\" data-end=\"3514\"\u003e\n\u003ctd data-start=\"3470\" data-end=\"3485\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"3485\" data-end=\"3514\" data-col-size=\"sm\"\u003eXLPE Cable Curing Chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3515\" data-end=\"3556\"\u003e\n\u003ctd data-start=\"3515\" data-end=\"3535\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"3535\" data-end=\"3556\" data-col-size=\"sm\"\u003eAmbient to 200 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3557\" data-end=\"3610\"\u003e\n\u003ctd data-start=\"3557\" data-end=\"3582\" data-col-size=\"sm\"\u003eTemperature Controller\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3582\" data-end=\"3610\"\u003eDigital \/ PID controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3611\" data-end=\"3642\"\u003e\n\u003ctd data-start=\"3611\" data-end=\"3632\" data-col-size=\"sm\"\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3632\" data-end=\"3642\"\u003ePT-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3643\" data-end=\"3689\"\u003e\n\u003ctd data-start=\"3643\" data-end=\"3660\" data-col-size=\"sm\"\u003eHeating System\u003c\/td\u003e\n\u003ctd data-start=\"3660\" data-end=\"3689\" data-col-size=\"sm\"\u003eElectric heating elements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3690\" data-end=\"3738\"\u003e\n\u003ctd data-start=\"3690\" data-end=\"3708\" data-col-size=\"sm\"\u003eAir Circulation\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3708\" data-end=\"3738\"\u003eForced air circulation fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3739\" data-end=\"3774\"\u003e\n\u003ctd data-start=\"3739\" data-end=\"3755\" data-col-size=\"sm\"\u003eInner Chamber\u003c\/td\u003e\n\u003ctd data-start=\"3755\" data-end=\"3774\" data-col-size=\"sm\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3775\" data-end=\"3816\"\u003e\n\u003ctd data-start=\"3775\" data-end=\"3788\" data-col-size=\"sm\"\u003eOuter Body\u003c\/td\u003e\n\u003ctd data-start=\"3788\" data-end=\"3816\" data-col-size=\"sm\"\u003ePowder coated mild steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3817\" data-end=\"3861\"\u003e\n\u003ctd data-start=\"3817\" data-end=\"3830\" data-col-size=\"sm\"\u003eInsulation\u003c\/td\u003e\n\u003ctd data-start=\"3830\" data-end=\"3861\" data-col-size=\"sm\"\u003eHigh temperature insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3862\" data-end=\"3904\"\u003e\n\u003ctd data-start=\"3862\" data-end=\"3877\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3877\" data-end=\"3904\" data-col-size=\"sm\"\u003e230 V \/ 415 V AC, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3905\" data-end=\"3956\"\u003e\n\u003ctd data-start=\"3905\" data-end=\"3919\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3919\" data-end=\"3956\"\u003eXLPE cable curing and aging tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Eindustries","offers":[{"title":"Default Title","offer_id":52339075612853,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/8595\/8069\/files\/xlpe-wire-cable-curing-chamber-fully-automatic-with-plc.jpg?v=1773211589","url":"https:\/\/eindustries.in\/products\/xlpe-cable-curing-chamber","provider":"Eindustries","version":"1.0","type":"link"}