{"product_id":"hot-cold-test-chamber","title":"Hot \u0026 Cold Test Chamber","description":"\u003cp data-start=\"299\" data-end=\"578\"\u003eThe \u003cstrong data-start=\"303\" data-end=\"330\"\u003eHot \u0026amp; Cold Test Chamber\u003c\/strong\u003e offered by \u003cstrong data-start=\"342\" data-end=\"376\"\u003ePrism Test \u0026amp; Measure Pvt. Ltd.\u003c\/strong\u003e is an advanced environmental testing system designed to simulate \u003cstrong data-start=\"442\" data-end=\"511\"\u003eextreme temperature variations and controlled humidity conditions\u003c\/strong\u003e for evaluating product durability, reliability, and performance.\u003c\/p\u003e\n\u003cp data-start=\"580\" data-end=\"797\"\u003eThis chamber is engineered to reproduce rapid temperature changes, enabling manufacturers and researchers to test how materials, components, and finished products behave under \u003cstrong data-start=\"756\" data-end=\"796\"\u003echallenging environmental conditions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"799\" data-end=\"1096\"\u003eEquipped with a \u003cstrong data-start=\"815\" data-end=\"864\"\u003ePLC-based control system with touchscreen HMI\u003c\/strong\u003e, the chamber provides precise monitoring and programming of test parameters. The \u003cstrong data-start=\"946\" data-end=\"1041\"\u003estainless steel interior, insulated construction, and high-performance refrigeration system\u003c\/strong\u003e ensure consistent performance and long service life.\u003c\/p\u003e\n\u003cp data-start=\"1098\" data-end=\"1365\"\u003eHot \u0026amp; Cold Test Chambers are widely used in industries such as \u003cstrong data-start=\"1161\" data-end=\"1254\"\u003eelectronics, automotive, aerospace, packaging, pharmaceuticals, and research laboratories\u003c\/strong\u003e to ensure products meet international quality and reliability standards.\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"relative inline-flex items-center\"\u003e\u003cbutton class=\"ms-1 flex h-[25px] text-[10px] leading-[13px] rounded-xl corner-superellipse\/1.1 items-center justify-center gap-1 px-2 relative text-token-text-secondary! hover:text-token-text-primary! hover:bg-token-bg-secondary dark:bg-token-main-surface-secondary dark:hover:bg-token-bg-secondary bg-[#f4f4f4]\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" class=\"h-[16px] w-[16px] object-contain text-token-text-primary! flex-none icon-sm\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-fk4oovux.svg#554074\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/button\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1367\" data-end=\"1370\"\u003e\n\u003ch1 data-section-id=\"u0ybrq\" data-start=\"1372\" data-end=\"1386\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1388\" data-end=\"2361\"\u003e• Wide \u003cstrong data-start=\"1395\" data-end=\"1447\"\u003etemperature testing range from −80 °C to +200 °C\u003c\/strong\u003e for extreme condition simulation\u003cbr data-start=\"1480\" data-end=\"1483\"\u003e• \u003cstrong data-start=\"1485\" data-end=\"1516\"\u003eHumidity control capability\u003c\/strong\u003e to simulate real environmental conditions\u003cbr data-start=\"1558\" data-end=\"1561\"\u003e• \u003cstrong data-start=\"1563\" data-end=\"1612\"\u003ePLC based control system with touchscreen HMI\u003c\/strong\u003e for precise monitoring and programming\u003cbr data-start=\"1651\" data-end=\"1654\"\u003e• \u003cstrong data-start=\"1656\" data-end=\"1689\"\u003eAdvanced refrigeration system\u003c\/strong\u003e with environmentally friendly CFC-free refrigerants\u003cbr data-start=\"1741\" data-end=\"1744\"\u003e• \u003cstrong data-start=\"1746\" data-end=\"1788\"\u003eSingle stage or cascade cooling system\u003c\/strong\u003e for efficient temperature control\u003cbr data-start=\"1822\" data-end=\"1825\"\u003e• \u003cstrong data-start=\"1827\" data-end=\"1861\"\u003eRapid heating and cooling rate\u003c\/strong\u003e from 1 °C\/min to 15 °C\/min\u003cbr data-start=\"1888\" data-end=\"1891\"\u003e• \u003cstrong data-start=\"1893\" data-end=\"1929\"\u003eStainless steel interior chamber\u003c\/strong\u003e for corrosion resistance and durability\u003cbr data-start=\"1969\" data-end=\"1972\"\u003e• \u003cstrong data-start=\"1974\" data-end=\"2011\"\u003eHeavy duty insulated construction\u003c\/strong\u003e for energy efficiency and stable temperature control\u003cbr data-start=\"2064\" data-end=\"2067\"\u003e• \u003cstrong data-start=\"2069\" data-end=\"2101\"\u003eOptional data logging system\u003c\/strong\u003e for performance monitoring and report generation\u003cbr data-start=\"2150\" data-end=\"2153\"\u003e• \u003cstrong data-start=\"2155\" data-end=\"2185\"\u003eSafety protection features\u003c\/strong\u003e including overheat protection, circuit breakers, and emergency stop\u003cbr data-start=\"2253\" data-end=\"2256\"\u003e• Custom chamber capacities available based on testing requirements \u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"relative inline-flex items-center\"\u003e\u003cbutton class=\"ms-1 flex h-[25px] text-[10px] leading-[13px] rounded-xl corner-superellipse\/1.1 items-center justify-center gap-1 px-2 relative text-token-text-secondary! hover:text-token-text-primary! hover:bg-token-bg-secondary dark:bg-token-main-surface-secondary dark:hover:bg-token-bg-secondary bg-[#f4f4f4]\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" class=\"h-[16px] w-[16px] object-contain text-token-text-primary! flex-none icon-sm\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-fk4oovux.svg#554074\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/button\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2363\" data-end=\"2366\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"2368\" data-end=\"2394\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2396\" data-end=\"3425\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2396\" data-end=\"2425\"\u003e\n\u003ctr data-start=\"2396\" data-end=\"2425\"\u003e\n\u003cth data-start=\"2396\" data-end=\"2408\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2408\" data-end=\"2425\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2455\" data-end=\"3425\"\u003e\n\u003ctr data-start=\"2455\" data-end=\"2501\"\u003e\n\u003ctd data-start=\"2455\" data-end=\"2474\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2457\" data-end=\"2473\"\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2474\" data-end=\"2501\" data-col-size=\"md\"\u003eHot \u0026amp; Cold Test Chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2502\" data-end=\"2547\"\u003e\n\u003ctd data-start=\"2502\" data-end=\"2526\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2504\" data-end=\"2525\"\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2526\" data-end=\"2547\"\u003e−80 °C to +200 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2548\" data-end=\"2589\"\u003e\n\u003ctd data-start=\"2548\" data-end=\"2569\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2550\" data-end=\"2568\"\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2569\" data-end=\"2589\"\u003e10% RH to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2590\" data-end=\"2678\"\u003e\n\u003ctd data-start=\"2590\" data-end=\"2619\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2592\" data-end=\"2618\"\u003eHeating \/ Cooling Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2619\" data-end=\"2678\"\u003e1 °C \/ min to 15 °C \/ min (custom ramp rates available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2679\" data-end=\"2739\"\u003e\n\u003ctd data-start=\"2679\" data-end=\"2700\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2699\"\u003eControl System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2700\" data-end=\"2739\" data-col-size=\"md\"\u003eIntegrated PLC with Touchscreen HMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2740\" data-end=\"2834\"\u003e\n\u003ctd data-start=\"2740\" data-end=\"2767\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2742\" data-end=\"2766\"\u003eRefrigeration System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2767\" data-end=\"2834\"\u003eHigh performance refrigeration system with CFC-free refrigerant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2835\" data-end=\"2896\"\u003e\n\u003ctd data-start=\"2835\" data-end=\"2854\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2837\" data-end=\"2853\"\u003eCooling Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2854\" data-end=\"2896\"\u003eSingle-stage or cascade cooling system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2897\" data-end=\"2951\"\u003e\n\u003ctd data-start=\"2897\" data-end=\"2932\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2899\" data-end=\"2931\"\u003eConstruction (Inner Chamber)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2932\" data-end=\"2951\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2952\" data-end=\"3012\"\u003e\n\u003ctd data-start=\"2952\" data-end=\"2984\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2954\" data-end=\"2983\"\u003eConstruction (Outer Body)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2984\" data-end=\"3012\" data-col-size=\"md\"\u003ePowder coated mild steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3013\" data-end=\"3073\"\u003e\n\u003ctd data-start=\"3013\" data-end=\"3030\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3015\" data-end=\"3029\"\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3030\" data-end=\"3073\" data-col-size=\"md\"\u003eHigh efficiency insulated chamber walls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3074\" data-end=\"3140\"\u003e\n\u003ctd data-start=\"3074\" data-end=\"3093\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3076\" data-end=\"3092\"\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3093\" data-end=\"3140\"\u003eOptional integrated data acquisition system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3141\" data-end=\"3219\"\u003e\n\u003ctd data-start=\"3141\" data-end=\"3162\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3143\" data-end=\"3161\"\u003eSafety Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3162\" data-end=\"3219\" data-col-size=\"md\"\u003eOverheat protection, circuit breakers, emergency stop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3220\" data-end=\"3285\"\u003e\n\u003ctd data-start=\"3220\" data-end=\"3241\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3222\" data-end=\"3240\"\u003eCapacity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3241\" data-end=\"3285\" data-col-size=\"md\"\u003e50 L – 1000 L (custom designs available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3286\" data-end=\"3334\"\u003e\n\u003ctd data-start=\"3286\" data-end=\"3305\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3288\" data-end=\"3304\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3305\" data-end=\"3334\"\u003eThree Phase, 415 V, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3335\" data-end=\"3425\"\u003e\n\u003ctd data-start=\"3335\" data-end=\"3361\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3337\" data-end=\"3360\"\u003eStandard Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3361\" data-end=\"3386\"\u003eIEC6008, MIL, JSS55555\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Eindustries","offers":[{"title":"Default Title","offer_id":52335931195573,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"url":"https:\/\/eindustries.in\/products\/hot-cold-test-chamber","provider":"Eindustries","version":"1.0","type":"link"}