{"product_id":"high-voltage-breakdown-tester","title":"HIGH VOLTAGE BREAKDOWN TESTER","description":"\u003cp data-start=\"338\" data-end=\"563\"\u003eThe \u003cstrong data-start=\"342\" data-end=\"375\"\u003eHigh Voltage Breakdown Tester\u003c\/strong\u003e from \u003cstrong data-start=\"381\" data-end=\"415\"\u003ePrism Test \u0026amp; Measure Pvt. Ltd.\u003c\/strong\u003e is designed for \u003cstrong data-start=\"432\" data-end=\"560\"\u003edielectric strength and high voltage breakdown testing of electrical components, cables, insulation materials, and equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"565\" data-end=\"799\"\u003eThe instrument provides \u003cstrong data-start=\"589\" data-end=\"684\"\u003econtrolled high voltage output with accurate monitoring of test voltage and leakage current\u003c\/strong\u003e, making it suitable for \u003cstrong data-start=\"709\" data-end=\"798\"\u003elaboratories, production testing, quality control, and safety compliance applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"806\" data-end=\"823\"\u003eKey Features\u003c\/h2\u003e\n\u003cp data-start=\"824\" data-end=\"1281\"\u003e• voltage variation through variac control knob\u003cbr data-start=\"871\" data-end=\"874\"\u003e• audio and visual alarm indication when high voltage ON \/ OFF\u003cbr data-start=\"936\" data-end=\"939\"\u003e• 3½ digit meter for test voltage (kV) indication\u003cbr data-start=\"988\" data-end=\"991\"\u003e• 3½ digit meter for leakage current (mA) indication\u003cbr data-start=\"1043\" data-end=\"1046\"\u003e• programmable timer to set test duration\u003cbr data-start=\"1087\" data-end=\"1090\"\u003e• timer ON \/ OFF control using toggle switch\u003cbr data-start=\"1134\" data-end=\"1137\"\u003e• trip current setting through switch and potentiometer\u003cbr data-start=\"1192\" data-end=\"1195\"\u003e• input fuse protection for safety\u003cbr data-start=\"1229\" data-end=\"1232\"\u003e• test ON \/ OFF operation through toggle switch\u003c\/p\u003e\n\u003chr data-start=\"1283\" data-end=\"1286\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1288\" data-end=\"1317\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1319\" data-end=\"1713\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1319\" data-end=\"1348\"\u003e\n\u003ctr data-start=\"1319\" data-end=\"1348\"\u003e\n\u003cth data-start=\"1319\" data-end=\"1331\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1331\" data-end=\"1348\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1359\" data-end=\"1713\"\u003e\n\u003ctr data-start=\"1359\" data-end=\"1399\"\u003e\n\u003ctd data-start=\"1359\" data-end=\"1380\" data-col-size=\"sm\"\u003eInput Power Supply\u003c\/td\u003e\n\u003ctd data-start=\"1380\" data-end=\"1399\" data-col-size=\"md\"\u003e230 V AC, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1400\" data-end=\"1465\"\u003e\n\u003ctd data-start=\"1400\" data-end=\"1410\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"1410\" data-end=\"1465\" data-col-size=\"md\"\u003e3½ digit 7 segment red LED display for Test Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1466\" data-end=\"1527\"\u003e\n\u003ctd data-start=\"1466\" data-end=\"1469\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1469\" data-end=\"1527\" data-col-size=\"md\"\u003e3½ digit 7 segment red LED display for Leakage Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1528\" data-end=\"1573\"\u003e\n\u003ctd data-start=\"1528\" data-end=\"1539\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"1539\" data-end=\"1573\" data-col-size=\"md\"\u003e±2% of reading ±3 digit for kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1574\" data-end=\"1613\"\u003e\n\u003ctd data-start=\"1574\" data-end=\"1577\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1577\" data-end=\"1613\" data-col-size=\"md\"\u003e±1.5% of reading ±2 digit for mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1614\" data-end=\"1675\"\u003e\n\u003ctd data-start=\"1614\" data-end=\"1628\" data-col-size=\"sm\"\u003eTimer Range\u003c\/td\u003e\n\u003ctd data-start=\"1628\" data-end=\"1675\" data-col-size=\"md\"\u003e0 to 999 seconds with Timer ON \/ OFF switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1676\" data-end=\"1713\"\u003e\n\u003ctd data-start=\"1676\" data-end=\"1690\" data-col-size=\"sm\"\u003eIndications\u003c\/td\u003e\n\u003ctd data-start=\"1690\" data-end=\"1713\" data-col-size=\"md\"\u003eTrip, HV ON, HV OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Eindustries","offers":[{"title":"Default Title","offer_id":52335300837557,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"url":"https:\/\/eindustries.in\/products\/high-voltage-breakdown-tester","provider":"Eindustries","version":"1.0","type":"link"}