{"product_id":"decade-capacitance-box-1","title":"DECADE CAPACITANCE BOX","description":"\u003cp data-start=\"85\" data-end=\"524\"\u003eThe \u003cstrong data-start=\"89\" data-end=\"115\"\u003eDecade Capacitance Box\u003c\/strong\u003e from \u003cstrong data-start=\"121\" data-end=\"155\"\u003ePrism Test \u0026amp; Measure Pvt. Ltd.\u003c\/strong\u003e is a precision testing instrument designed to provide \u003cstrong data-start=\"210\" data-end=\"256\"\u003eaccurate and selectable capacitance values\u003c\/strong\u003e for calibration, testing, and circuit development applications. It is widely used in \u003cstrong data-start=\"342\" data-end=\"432\"\u003eelectronics laboratories, calibration labs, educational institutes, and R\u0026amp;D facilities\u003c\/strong\u003e for testing and verifying \u003cstrong data-start=\"459\" data-end=\"521\"\u003ecapacitors, measuring instruments, and electronic circuits\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"526\" data-end=\"796\"\u003eThe capacitance value can be easily selected using \u003cstrong data-start=\"577\" data-end=\"603\"\u003erotary decade switches\u003c\/strong\u003e, enabling quick and precise adjustments. Built with \u003cstrong data-start=\"656\" data-end=\"719\"\u003ehigh stability capacitors and reliable switching mechanisms\u003c\/strong\u003e, the unit ensures \u003cstrong data-start=\"738\" data-end=\"795\"\u003estable performance and dependable measurement results\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"803\" data-end=\"819\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"822\" data-end=\"900\"\u003e\n\u003cstrong data-start=\"822\" data-end=\"848\"\u003eWide capacitance range\u003c\/strong\u003e suitable for calibration and testing applications\u003c\/li\u003e\n\u003cli data-start=\"903\" data-end=\"976\"\u003e\n\u003cstrong data-start=\"903\" data-end=\"929\"\u003eRotary decade switches\u003c\/strong\u003e for quick and accurate capacitance selection\u003c\/li\u003e\n\u003cli data-start=\"979\" data-end=\"1035\"\u003e\n\u003cstrong data-start=\"979\" data-end=\"1008\"\u003eHigh stability capacitors\u003c\/strong\u003e for reliable performance\u003c\/li\u003e\n\u003cli data-start=\"1038\" data-end=\"1086\"\u003e\u003cstrong data-start=\"1038\" data-end=\"1084\"\u003eLow loss and stable output characteristics\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1089\" data-end=\"1146\"\u003e\n\u003cstrong data-start=\"1089\" data-end=\"1125\"\u003e4 mm safety terminal connections\u003c\/strong\u003e for secure testing\u003c\/li\u003e\n\u003cli data-start=\"1149\" data-end=\"1190\"\u003e\u003cstrong data-start=\"1149\" data-end=\"1188\"\u003eCompact and rugged bench-top design\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1193\" data-end=\"1289\"\u003eSuitable for \u003cstrong data-start=\"1206\" data-end=\"1289\"\u003eelectronic circuit testing, instrument calibration, and educational experiments\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1296\" data-end=\"1324\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1326\" data-end=\"1783\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1326\" data-end=\"1355\"\u003e\n\u003ctr data-start=\"1326\" data-end=\"1355\"\u003e\n\u003cth data-start=\"1326\" data-end=\"1338\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1338\" data-end=\"1355\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1366\" data-end=\"1783\"\u003e\n\u003ctr data-start=\"1366\" data-end=\"1415\"\u003e\n\u003ctd data-start=\"1366\" data-end=\"1390\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1368\" data-end=\"1389\"\u003eCapacitance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1390\" data-end=\"1415\" data-col-size=\"md\"\u003e100 pF to 11,111.1 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1416\" data-end=\"1496\"\u003e\n\u003ctd data-start=\"1416\" data-end=\"1435\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1418\" data-end=\"1434\"\u003eDecade Steps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1435\" data-end=\"1496\"\u003e100 pF, 1 nF, 10 nF, 100 nF, 1 µF, 10 µF, 100 µF, 1000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1497\" data-end=\"1519\"\u003e\n\u003ctd data-start=\"1497\" data-end=\"1512\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1499\" data-end=\"1511\"\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1512\" data-end=\"1519\"\u003e±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1520\" data-end=\"1558\"\u003e\n\u003ctd data-start=\"1520\" data-end=\"1547\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1522\" data-end=\"1546\"\u003eResidual Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1547\" data-end=\"1558\" data-col-size=\"md\"\u003e\u0026lt; 50 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1559\" data-end=\"1603\"\u003e\n\u003ctd data-start=\"1559\" data-end=\"1587\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1561\" data-end=\"1586\"\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1587\" data-end=\"1603\"\u003e10°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1604\" data-end=\"1645\"\u003e\n\u003ctd data-start=\"1604\" data-end=\"1630\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1606\" data-end=\"1629\"\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1630\" data-end=\"1645\"\u003e5°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1646\" data-end=\"1696\"\u003e\n\u003ctd data-start=\"1646\" data-end=\"1669\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1648\" data-end=\"1668\"\u003eOutput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1669\" data-end=\"1696\" data-col-size=\"md\"\u003eØ 4 mm Safety Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1697\" data-end=\"1753\"\u003e\n\u003ctd data-start=\"1697\" data-end=\"1714\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1699\" data-end=\"1713\"\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1714\" data-end=\"1753\" data-col-size=\"md\"\u003e470 mm (W) × 100 mm (D) × 80 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1754\" data-end=\"1783\"\u003e\n\u003ctd data-start=\"1754\" data-end=\"1767\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1756\" data-end=\"1766\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1767\" data-end=\"1783\" data-col-size=\"md\"\u003eApprox. 2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Eindustries","offers":[{"title":"Default Title","offer_id":52333137035445,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/8595\/8069\/files\/DecadeCapacitanceBox.jpg?v=1773057326","url":"https:\/\/eindustries.in\/products\/decade-capacitance-box-1","provider":"Eindustries","version":"1.0","type":"link"}