{"product_id":"ac-dc-high-current-source","title":"AC \u0026 DC HIGH CURRENT SOURCE","description":"\u003cp data-start=\"285\" data-end=\"701\"\u003eThe \u003cstrong data-start=\"289\" data-end=\"320\"\u003eAC \u0026amp; DC High Current Source\u003c\/strong\u003e from \u003cstrong data-start=\"326\" data-end=\"360\"\u003ePrism Test \u0026amp; Measure Pvt. Ltd.\u003c\/strong\u003e is a high-performance testing instrument designed to generate controlled \u003cstrong data-start=\"434\" data-end=\"482\"\u003ehigh current outputs in both AC and DC modes\u003c\/strong\u003e for testing electrical equipment, components, and protection systems. It is widely used for \u003cstrong data-start=\"575\" data-end=\"700\"\u003etesting circuit breakers, busbars, relays, current transformers (CTs), switchgear, and high-current electrical components\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"703\" data-end=\"1092\"\u003eThis robust testing system provides \u003cstrong data-start=\"739\" data-end=\"816\"\u003estable and adjustable high current output with precise digital monitoring\u003c\/strong\u003e, ensuring accurate performance evaluation of electrical devices under load conditions. The equipment is equipped with \u003cstrong data-start=\"935\" data-end=\"1053\"\u003edigital meters, variac control for smooth current adjustment, programmable timer functions, and safety protections\u003c\/strong\u003e to ensure reliable and safe operation.\u003c\/p\u003e\n\u003cp data-start=\"1094\" data-end=\"1351\"\u003eDesigned for \u003cstrong data-start=\"1107\" data-end=\"1230\"\u003eindustrial testing laboratories, electrical panel manufacturers, power plants, substations, and maintenance departments\u003c\/strong\u003e, the AC \u0026amp; DC High Current Source delivers dependable performance for high-current testing and verification applications.\u003c\/p\u003e\n\u003chr data-start=\"1353\" data-end=\"1356\"\u003e\n\u003ch1 data-section-id=\"u0ybrq\" data-start=\"1358\" data-end=\"1372\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1374\" data-end=\"2131\"\u003e• Generates \u003cstrong data-start=\"1386\" data-end=\"1420\"\u003ehigh AC and DC current outputs\u003c\/strong\u003e for electrical testing applications\u003cbr data-start=\"1456\" data-end=\"1459\"\u003e• \u003cstrong data-start=\"1461\" data-end=\"1479\"\u003eDigital meters\u003c\/strong\u003e for accurate monitoring of current and voltage\u003cbr data-start=\"1526\" data-end=\"1529\"\u003e• Smooth current adjustment using \u003cstrong data-start=\"1563\" data-end=\"1592\"\u003eheavy-duty variac control\u003c\/strong\u003e\u003cbr data-start=\"1592\" data-end=\"1595\"\u003e• \u003cstrong data-start=\"1597\" data-end=\"1624\"\u003eMultiple current ranges\u003c\/strong\u003e for flexible testing requirements\u003cbr data-start=\"1658\" data-end=\"1661\"\u003e• \u003cstrong data-start=\"1663\" data-end=\"1711\"\u003eStable output with low ripple and distortion\u003c\/strong\u003e\u003cbr data-start=\"1711\" data-end=\"1714\"\u003e• \u003cstrong data-start=\"1716\" data-end=\"1761\"\u003eDigital timer with automatic test control\u003c\/strong\u003e\u003cbr data-start=\"1761\" data-end=\"1764\"\u003e• \u003cstrong data-start=\"1766\" data-end=\"1807\"\u003eOverload and short-circuit protection\u003c\/strong\u003e for operator safety\u003cbr data-start=\"1827\" data-end=\"1830\"\u003e• \u003cstrong data-start=\"1832\" data-end=\"1859\"\u003eMCB based power control\u003c\/strong\u003e for reliable operation\u003cbr data-start=\"1882\" data-end=\"1885\"\u003e• \u003cstrong data-start=\"1887\" data-end=\"1918\"\u003eHeavy-duty output terminals\u003c\/strong\u003e suitable for high-current connections\u003cbr data-start=\"1956\" data-end=\"1959\"\u003e• Rugged and compact design suitable for \u003cstrong data-start=\"2000\" data-end=\"2042\"\u003eindustrial and laboratory environments\u003c\/strong\u003e\u003cbr data-start=\"2042\" data-end=\"2045\"\u003e• Ideal for \u003cstrong data-start=\"2057\" data-end=\"2131\"\u003ecircuit breaker testing, CT testing, relay testing, and busbar testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"2133\" data-end=\"2136\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"2138\" data-end=\"2164\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2166\" data-end=\"3095\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2166\" data-end=\"2195\"\u003e\n\u003ctr data-start=\"2166\" data-end=\"2195\"\u003e\n\u003cth data-start=\"2166\" data-end=\"2178\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2178\" data-end=\"2195\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2225\" data-end=\"3095\"\u003e\n\u003ctr data-start=\"2225\" data-end=\"2275\"\u003e\n\u003ctd data-start=\"2225\" data-end=\"2244\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2227\" data-end=\"2243\"\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2244\" data-end=\"2275\" data-col-size=\"md\"\u003eAC \u0026amp; DC High Current Source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2276\" data-end=\"2331\"\u003e\n\u003ctd data-start=\"2276\" data-end=\"2301\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2278\" data-end=\"2300\"\u003eInput Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2301\" data-end=\"2331\" data-col-size=\"md\"\u003e230 V AC \/ 415 V AC, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2332\" data-end=\"2408\"\u003e\n\u003ctd data-start=\"2332\" data-end=\"2358\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2334\" data-end=\"2357\"\u003eOutput Current (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2358\" data-end=\"2408\" data-col-size=\"md\"\u003eUp to 500 A \/ 1000 A (custom ranges available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2409\" data-end=\"2484\"\u003e\n\u003ctd data-start=\"2409\" data-end=\"2435\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2411\" data-end=\"2434\"\u003eOutput Current (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2435\" data-end=\"2484\" data-col-size=\"md\"\u003eUp to 200 A \/ 500 A (custom ranges available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2485\" data-end=\"2541\"\u003e\n\u003ctd data-start=\"2485\" data-end=\"2506\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2487\" data-end=\"2505\"\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2506\" data-end=\"2541\" data-col-size=\"md\"\u003eLow voltage high current output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2542\" data-end=\"2598\"\u003e\n\u003ctd data-start=\"2542\" data-end=\"2567\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2544\" data-end=\"2566\"\u003eCurrent Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2567\" data-end=\"2598\" data-col-size=\"md\"\u003eVariac based smooth control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2599\" data-end=\"2657\"\u003e\n\u003ctd data-start=\"2599\" data-end=\"2614\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2601\" data-end=\"2613\"\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2614\" data-end=\"2657\" data-col-size=\"md\"\u003eDigital Ammeter for current measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2658\" data-end=\"2719\"\u003e\n\u003ctd data-start=\"2658\" data-end=\"2670\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2660\" data-end=\"2669\"\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2670\" data-end=\"2719\" data-col-size=\"md\"\u003eDigital timer for controlled testing duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2720\" data-end=\"2756\"\u003e\n\u003ctd data-start=\"2720\" data-end=\"2735\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2722\" data-end=\"2734\"\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2735\" data-end=\"2756\" data-col-size=\"md\"\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2757\" data-end=\"2824\"\u003e\n\u003ctd data-start=\"2757\" data-end=\"2780\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2759\" data-end=\"2779\"\u003eOutput Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2780\" data-end=\"2824\" data-col-size=\"md\"\u003eHeavy duty high-current output terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2825\" data-end=\"2894\"\u003e\n\u003ctd data-start=\"2825\" data-end=\"2842\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2827\" data-end=\"2841\"\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2842\" data-end=\"2894\" data-col-size=\"md\"\u003eOverload protection and short circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2895\" data-end=\"2943\"\u003e\n\u003ctd data-start=\"2895\" data-end=\"2915\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2897\" data-end=\"2914\"\u003ePower Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2915\" data-end=\"2943\" data-col-size=\"md\"\u003eMCB based ON\/OFF control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2944\" data-end=\"3012\"\u003e\n\u003ctd data-start=\"2944\" data-end=\"2965\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2946\" data-end=\"2964\"\u003eCooling System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2965\" data-end=\"3012\" data-col-size=\"md\"\u003eForced air cooling for continuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3013\" data-end=\"3095\"\u003e\n\u003ctd data-start=\"3013\" data-end=\"3032\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3015\" data-end=\"3031\"\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3032\" data-end=\"3095\" data-col-size=\"md\"\u003eHeavy-duty metal enclosure with industrial grade components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Eindustries","offers":[{"title":"Default Title","offer_id":52335338881205,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"url":"https:\/\/eindustries.in\/products\/ac-dc-high-current-source","provider":"Eindustries","version":"1.0","type":"link"}