{"product_id":"3-phase-secondary-injection-kit","title":"3 PHASE SECONDARY INJECTION KIT","description":"\u003cp data-start=\"251\" data-end=\"555\"\u003eThe \u003cstrong data-start=\"255\" data-end=\"290\"\u003e3 Phase Secondary Injection Kit\u003c\/strong\u003e offered by \u003cstrong data-start=\"302\" data-end=\"336\"\u003ePrism Test \u0026amp; Measure Pvt. Ltd.\u003c\/strong\u003e is a precision testing instrument designed for testing, calibration, and commissioning of protection relays, current transformers (CTs), potential transformers (PTs), and other protection devices used in power systems.\u003c\/p\u003e\n\u003cp data-start=\"557\" data-end=\"848\"\u003eThis advanced testing system provides \u003cstrong data-start=\"595\" data-end=\"647\"\u003eaccurate three-phase voltage and current outputs\u003c\/strong\u003e to simulate real power system conditions. It enables engineers and technicians to verify relay performance, test protection schemes, and evaluate system behavior under different electrical conditions.\u003c\/p\u003e\n\u003cp data-start=\"850\" data-end=\"1260\"\u003eThe instrument features \u003cstrong data-start=\"874\" data-end=\"990\"\u003edigital metering, adjustable voltage and current outputs, programmable settings, and stable sinusoidal waveforms\u003c\/strong\u003e, ensuring reliable testing results. With built-in safety protections and high-accuracy measurements, the 3 Phase Secondary Injection Kit is widely used in \u003cstrong data-start=\"1146\" data-end=\"1259\"\u003epower plants, electrical substations, transmission networks, switchgear testing, and industrial power systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1262\" data-end=\"1265\"\u003e\n\u003ch1 data-section-id=\"u0ybrq\" data-start=\"1267\" data-end=\"1281\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1283\" data-end=\"2187\"\u003e• 4½ digit digital meters to display set voltage, current, and universal parameters\u003cbr data-start=\"1366\" data-end=\"1369\"\u003e• High precision \u003cstrong data-start=\"1386\" data-end=\"1439\"\u003ethree-phase voltage and current output simulation\u003c\/strong\u003e\u003cbr data-start=\"1439\" data-end=\"1442\"\u003e• Voltage and current adjustment using \u003cstrong data-start=\"1481\" data-end=\"1526\"\u003ecoarse and fine multi-turn potentiometers\u003c\/strong\u003e\u003cbr data-start=\"1526\" data-end=\"1529\"\u003e• Frequency adjustment using a \u003cstrong data-start=\"1560\" data-end=\"1588\"\u003emulti-turn potentiometer\u003c\/strong\u003e\u003cbr data-start=\"1588\" data-end=\"1591\"\u003e• \u003cstrong data-start=\"1593\" data-end=\"1620\"\u003ePower factor adjustment\u003c\/strong\u003e using push-button controls\u003cbr data-start=\"1647\" data-end=\"1650\"\u003e• Digital universal meter to display \u003cstrong data-start=\"1687\" data-end=\"1736\"\u003ePF, Power (W), VA, VAr, and energy parameters\u003c\/strong\u003e\u003cbr data-start=\"1736\" data-end=\"1739\"\u003e• Separate output ports for \u003cstrong data-start=\"1767\" data-end=\"1804\"\u003evoltage channels (L1, L2, L3 \u0026amp; N)\u003c\/strong\u003e\u003cbr data-start=\"1804\" data-end=\"1807\"\u003e• Separate output ports for \u003cstrong data-start=\"1835\" data-end=\"1872\"\u003ecurrent channels (CT1, CT2 \u0026amp; CT3)\u003c\/strong\u003e\u003cbr data-start=\"1872\" data-end=\"1875\"\u003e• \u003cstrong data-start=\"1877\" data-end=\"1909\"\u003eProgrammable current display\u003c\/strong\u003e compatible with different CT ratios\u003cbr data-start=\"1945\" data-end=\"1948\"\u003e• \u003cstrong data-start=\"1950\" data-end=\"1985\"\u003eOutput and timer ON\/OFF control\u003c\/strong\u003e using toggle switches\u003cbr data-start=\"2007\" data-end=\"2010\"\u003e• \u003cstrong data-start=\"2012\" data-end=\"2046\"\u003eMCB based power ON\/OFF control\u003c\/strong\u003e for improved safety\u003cbr data-start=\"2066\" data-end=\"2069\"\u003e• Stable sinusoidal output with low harmonic distortion\u003cbr data-start=\"2124\" data-end=\"2127\"\u003e• Overload and short circuit protection for safe operation\u003c\/p\u003e\n\u003chr data-start=\"2189\" data-end=\"2192\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"2194\" data-end=\"2220\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2222\" data-end=\"3331\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2222\" data-end=\"2251\"\u003e\n\u003ctr data-start=\"2222\" data-end=\"2251\"\u003e\n\u003cth data-start=\"2222\" data-end=\"2234\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2234\" data-end=\"2251\" data-col-size=\"lg\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2281\" data-end=\"3331\"\u003e\n\u003ctr data-start=\"2281\" data-end=\"2328\"\u003e\n\u003ctd data-start=\"2281\" data-end=\"2293\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2283\" data-end=\"2292\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2293\" data-end=\"2328\" data-col-size=\"lg\"\u003e3 Phase Secondary Injection Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2329\" data-end=\"2380\"\u003e\n\u003ctd data-start=\"2329\" data-end=\"2354\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2331\" data-end=\"2353\"\u003eInput Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2354\" data-end=\"2380\"\u003e230 V AC, ±5 % @ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2381\" data-end=\"2457\"\u003e\n\u003ctd data-start=\"2381\" data-end=\"2408\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2383\" data-end=\"2407\"\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2408\" data-end=\"2457\"\u003e0 to 300 V (L-N) or 0 to 520 V Phase to Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2458\" data-end=\"2532\"\u003e\n\u003ctd data-start=\"2458\" data-end=\"2485\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2460\" data-end=\"2484\"\u003eOutput Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2485\" data-end=\"2532\"\u003e0 to 6 A and 0 to 50 A per phase continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2533\" data-end=\"2570\"\u003e\n\u003ctd data-start=\"2533\" data-end=\"2551\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2535\" data-end=\"2550\"\u003eOutput Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2551\" data-end=\"2570\"\u003e3 Phase, 4 Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2571\" data-end=\"2611\"\u003e\n\u003ctd data-start=\"2571\" data-end=\"2593\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2573\" data-end=\"2592\"\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2593\" data-end=\"2611\"\u003e45 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2612\" data-end=\"2669\"\u003e\n\u003ctd data-start=\"2612\" data-end=\"2637\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2614\" data-end=\"2636\"\u003ePower Factor Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2637\" data-end=\"2669\"\u003e0 (Lag) to Unity to 0 (Lead)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2670\" data-end=\"2782\"\u003e\n\u003ctd data-start=\"2670\" data-end=\"2687\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2672\" data-end=\"2686\"\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2687\" data-end=\"2782\"\u003e20 VA at FS on Voltage ranges, 30 VA at FS on 6A ranges, 250 VA at FS on 50A current ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2783\" data-end=\"2900\"\u003e\n\u003ctd data-start=\"2783\" data-end=\"2798\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2785\" data-end=\"2797\"\u003eMetering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2798\" data-end=\"2900\" data-col-size=\"lg\"\u003eDigital AC Voltmeter, Digital AC Ammeter, Universal meter for PF, W, VA, VAr and energy parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2901\" data-end=\"2929\"\u003e\n\u003ctd data-start=\"2901\" data-end=\"2916\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2903\" data-end=\"2915\"\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2916\" data-end=\"2929\" data-col-size=\"lg\"\u003eClass 0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2930\" data-end=\"2976\"\u003e\n\u003ctd data-start=\"2930\" data-end=\"2962\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2932\" data-end=\"2961\"\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2962\" data-end=\"2976\" data-col-size=\"lg\"\u003eTHD ≤ 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2977\" data-end=\"3105\"\u003e\n\u003ctd data-start=\"2977\" data-end=\"2992\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2979\" data-end=\"2991\"\u003eControls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2992\" data-end=\"3105\" data-col-size=\"lg\"\u003eVoltage and current setting by coarse and fine potentiometers; PF by push buttons; frequency by potentiometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3106\" data-end=\"3182\"\u003e\n\u003ctd data-start=\"3106\" data-end=\"3125\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3108\" data-end=\"3124\"\u003eOutput Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3125\" data-end=\"3182\" data-col-size=\"lg\"\u003eL1, L2, L3 \u0026amp; N, CT1 (Hi\/Lo), CT2 (Hi\/Lo), CT3 (Hi\/Lo)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3183\" data-end=\"3242\"\u003e\n\u003ctd data-start=\"3183\" data-end=\"3201\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3185\" data-end=\"3200\"\u003eProtections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3201\" data-end=\"3242\" data-col-size=\"lg\"\u003eOverload and short circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3243\" data-end=\"3300\"\u003e\n\u003ctd data-start=\"3243\" data-end=\"3260\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3245\" data-end=\"3259\"\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3260\" data-end=\"3300\" data-col-size=\"lg\"\u003e550 mm (W) × 650 mm (D) × 450 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3301\" data-end=\"3331\"\u003e\n\u003ctd data-start=\"3301\" data-end=\"3314\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3303\" data-end=\"3313\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3314\" data-end=\"3331\" data-col-size=\"lg\"\u003eApprox. 88 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Eindustries","offers":[{"title":"Default Title","offer_id":52335322792117,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"url":"https:\/\/eindustries.in\/products\/3-phase-secondary-injection-kit","provider":"Eindustries","version":"1.0","type":"link"}